Extra low pressure elements KCH 8040-C (F)
Application
Tap and low mineralized water up to 1 g/l
Model |
A, mm |
B, mm |
B' (ATD), mm |
C, mm |
D, mm |
Weight, kg |
KCH 8040-C |
1016.00 |
203.00 |
200.10 |
28.60 |
0.00 |
16.50 |
KCH 8040-F |
1016.00 |
203.00 |
200.10 |
28.60 |
0.00 |
16.50 |
KCH 8040-C3 |
1016.00 |
203.00 |
200.10 |
28.60 |
0.00 |
17.50 |
KCH 8040-F3 |
1016.00 |
203.00 |
200.10 |
28.60 |
0.00 |
17.50 |
Product description
Feature |
Reinforced by glass fiber (-C) or tape (-F) |
Membrane material |
Composite polyamide |
Membrane type |
ОРМ33К |
Design |
Spiral wound |
Application |
Desalination of brackish water |
Specification
Model |
Flux, GPD |
Rejection, % |
Area |
Spacer |
m2 |
ft2 |
mm |
mil |
KCH 8040-C |
12 400 |
99.10 / 98.30 |
41.00 |
440.00 |
0.66 |
26.00 |
KCH 8040-F |
12 400 |
99.10 / 98.30 |
41.00 |
440.00 |
0.66 |
26.00 |
KCH 8040-C3 |
10 500 |
99.10 / 98.30 |
35.00 |
375.00 |
0.86 |
34.00 |
KCH 8040-F3 |
10 500 |
99.10 / 98.30 |
35.00 |
375.00 |
0.86 |
34.00 |
TEST CONDITIONS: test solution of NaCl 500 mg/l, P=0,69 MPa, T=25°C , pH=7,5. Recovery - 15%
Nominal rejection is reached after 48 hours of continuous operation on test solution.
Minimal rejection of a new element after 20 minutes test on test solution.
Operating conditions and technical data for designing
Maximum pressure drop, MPa
|
0,07 |
Operation temperature, С1
|
4-45 |
рН at operation1
|
2-11 |
рН at chemical cleaning (short time operation)
|
2-11 (t≤45°C); 1-13 (t≤35°C)* |
Concentrate/permeate ratio on each element, min
|
5:1 |
Free chlorine content, mg/l max
|
0,1 |
Maximum feed flow, m3/hr
|
17 |
Chemical washing, T
|
T≤45;Т≤35;Т≤25 |
1) During continuous work with pH over 10,5 the temperature must not exceed 35°С
2) Flow of each element in a batch may vary +/-15%
*In case of chemical cleaning with a solution pH exceeding 11,5 or at the temperature level more than 45°С please contact original manufacturer for consultation.