Low pressure elements KH 4040-C1M1
Application
Brackish water up to 2 g/l
Model |
A, mm |
B, mm |
B' (ATD), mm |
C, mm |
D, mm |
Weight, kg |
KH 4040-C1М1 |
1016.00 |
100.00 |
0.00 |
19.10 |
26.70 |
4.05 |
Product description
Membrane material |
Composite polyamide |
Membrane type |
ОРМ32КМ |
Design |
Spiral wound |
Application |
Desalination of brackish water |
Specification
Model |
Flux, GPD |
Rejection, % |
Area |
Spacer |
m2 |
ft2 |
mm |
mil |
KH 4040-C1М1 |
2 400 |
99.40 / 99.20 |
8.00 |
86.00 |
0.72 |
28.00 |
TEST CONDITIONS: test solution of NaCl 1500 mg/l, P=1,0 MPa, T=25°C , pH=7,5. Recovery - 15%
Nominal rejection is reached after 48 hours of continuous operation on test solution.
Minimal rejection of a new element after 20 minutes test on test solution.
Operating conditions and technical data for designing
Maximum pressure drop, MPa
|
0,1 |
Operation temperature, С1
|
4-45 |
рН at operation
|
2-11 |
рН at chemical cleaning (short time operation)
|
2-11 (t≤45°C); 1-13 (t≤35°C)* |
Concentrate/permeate ratio on each element, min
|
5:1 |
Free chlorine content, mg/l max
|
0,1 |
Maximum feed flow, m3/hr
|
3,6 |
Chemical washing, T
|
Т≤45; Т≤35 |
1) During continuous work with pH over 10,5 the temperature must not exceed 35°С
2) Flow of each element in a batch may vary +/-15%